| Sensor power supply: | 5 – 12 V DC | 
| Consumption (idle at the lowest scanning speed) | 0,3 mA | 
| Output max. | 800 mA | 
| Sensing distance: | 0,5 – 1 m | 
| Wavelength equipment | 950 nm | 
| Optimal operating pressure | 0,3 – 0,5 MPa | 
| Maximum pressure | 0,8 MPa | 
| Time adjustment of valve opening | 1 – 30 s | 
| Fittings | G½ " | 
| Power consumption | 8,5 W | 
| Water flow at a pressure of 0.3 Mpa | 1,3 l | 
Product details
- For automatic flushing of urinals
 - For mounting frame A107S
 - For installing into the urinal mounting elements
 - For installation in plasterboard structures as well as walling-in
 
- Powered by the main electric supply, the power source must be purchased (12 V DC min 1 A) – recommended AEZ310
 - The removable cover plate – a combination of stainless steel/chrome–plated plastic
 - Setting via mini USB using free software available on the Alca website
 - Adjustable parameters: start and end time of registration, duration of flushing, automatic flush, allowing flooding, flooding time, variable settings hygienic rinse
 - Saving water using an adjustable flushing time
 - Material: stainless steel, chrome plated plastic
 
- EN 55014, EN 55022, EN 61000
 
| Quantity (package) | 16 pcs | 
| Quantity (pallet) | 256 pcs | 
| Dimensions (piece) | 175×137×160 mm | 
| Dimensions (package) | 595×435×395 mm | 
| Weight (piece) | 1,6724 kg | 
| Weight (package) | 26,7584 kg | 
| Weight (pallet) | 448,1344 kg | 
- Sensor box made of stainless steel
 - Screw set with valve
 - Plastic chromed cover frame
 - Tile template
 - Suction pad for removing the cover plate
 - Waterproof power connector
 - Infrared sensor adjustable via a USB port
 - Fixing material for attaching the covering frame: screw 3.5×32 – 4 pcs
 - Fixation set for attaching the box on the frame: screw 3.5×16 – 4 pcs
 - Screw fitting G1/2“
 
| K1941-ND | Frame cover | 
| M0599-ND | Suction pad 30 mm | 
| M0673-ND | Complete infra sensor with valve | 
| M0676-ND | Screw 3,5×32 | 
| M0693-ND | Plate for urinal sensor, chrome-plated | 
| M1579-ND | Valve R mini–battery operated | 
| M1580-ND | Valve R mini–power source | 
Downloads
| File Name | Size | Action | |
| ASP4 - Sensor settings - SW: D.pdf | 783.3 kB | 
                            
                                Download
                                 | 
                    |
| ASP4 - IRC Setup v. D – software for sensor configuration.zip | 1.98 MB | 
                            
                                Download
                                 | 
                    |
| ASP4 - Installation instructions.pdf | 5.42 MB | 
                            
                                Download
                                 | 
                    |
| ASP4 - CAD drawing.dwg | 137.06 kB | 
                            
                                Download
                                 | 
                    |
| ASP4 - CAD drawing.dxf | 376.9 kB | 
                            
                                Download
                                 | 
                    |
| ASP4 - Declaration of conformity.pdf | 163.76 kB | 
                            
                                Download
                                 |